IN-I8
Intelligent Health Examination Kiosk
Interactive health check kiosks provide non-evasive testing for weight, body mass index, body fat content, blood pressure and heart rate.
Each individual would be able to view their results on the kiosk, showing them how their results compare with national guidelines. They also receive a printout of their results.
- High speed, 1-minute measurement full body.
- Height precision, using the most advanced measurement equipment, Ensure measurement accuracy
- Intelligent, support ID/barcode login, full voice guidance Data connection, data can be connected to information platforms such as HIS
- Strong scalability, can be customized according to customer requirements
Technical parameter
Model |
IN-I8 |
|
Body height measurement (Optional function ) |
Measurement methods |
Non-contact ultrasonic probe measure body height |
Measurement result |
Display on the main screen |
|
Measuring range |
90cm~200cm |
|
Measurement accuracy |
±0.5cm |
|
Body weight measurement |
Measurement mode |
Automatic induction measurement |
Measurement result |
Display on the main screen |
|
Measuring range |
1Kg~500Kg |
|
Measurement accuracy |
±0.1Kg |
|
Weight accuracy level |
III level |
|
Body temperature measurement |
Operating environment temperature |
10~40℃ |
Storage temperature |
0~50℃ |
|
Relative humidity |
≤85% |
|
Body temperature measurement mode |
32.0~42.5℃ |
|
Environmental temperature measurement mode |
0~100℃ |
|
Accuracy |
≤±0.3℃ |
|
Power consumption |
≤120mw |
|
Measuring distance |
5 to 8 cm |
|
Automatic shut-down |
About 15 seconds |
|
Body fat measurement |
Measurement items |
Body fat percentage, body fat mass, muscle mass, body water percentage, body water content, visceral fat grade, lean body weight, ideal body weight, inorganic salt, protein, basal metabolic rate and other parameters |
Measurement method |
Multi-frequency four-electrode/whole body impedance measurement method |
|
Impedance measurement frequency |
50K Hz 、 250K Hz |
|
Human body impedance output |
Support printing human body impedance value |
|
Blood pressure measurement |
Measuring range |
Pressure (0~270)mmHg [(0~36)kpa] Pulse rate 40 times/minute~180 times/minute |
Measurement accuracy |
Pressure: within ±3mmHg (±0.4kpa) Pulse rate: within ±5% |
|
Storage capacity |
Can store 50 groups of measurement data for 2 users |
|
Blood pressure cuff size |
17cm~42cm |
|
Blood oxygen measurement |
Sensor |
Dual wavelength light emitting diode |
Wavelength |
Red light: 663nm Infrared light: 890nm |
|
Measuring range |
35%~100% |
|
Maximum average optical output power |
≤2mW |
|
Measurement error |
In the range of 70%~100%, the measurement accuracy is ±2% (% is the percentage of pulse oxygen saturation) |
|
Accuracy |
In the range of 70%-100% <2% |
|
Pulse rate measurement error |
30~250bpm The monitoring error is ±2bpm or ±%2, whichever is the largest |
|
Operating temperature |
5℃~40℃ |
|
Relative humidity |
15%~95% (non-condensing) |
|
Atmospheric pressure |
70kpa~106kpa |
|
Internet |
10/100M adaptive Ethernet RJ45 network port Support 2.4GWIFI, support IEEE 802.11 b/g/n |
|
Identification |
ID card can be selected according to user needs: second-generation resident ID card recognition, face recognition (non-3D face recognition), barcode, RFID and other identification methods |
|
Printing method |
The device has a built-in 57mm thermal microprinter (need to be customized) to print basic data, and can be directly connected to a designated A4 printer to print the medical report. |
|
Data upload method |
Can connect to HIS system or network platform via RJ45 or WIFI, upload data to designated server |
|
Input power |
AC 100~240V 50~60HZ |
|
Rated power |
<60VA |
|
Electric shock protection |
Class I Type B equipment |
|
Using environment temperature and humidity |
+5℃~+40℃ 15%RH~85%RH |
|
Storage environment temperature and humidity |
-20℃~+60℃ 10%RH~95RH |